J4
• 地质工程·环境工程 • Previous Articles Next Articles
LIU Feng1,2,ZHANG Lan-ying1,LIU Peng1,LANG Xian-ming2,YANG Nan2,LIANG Shu-qing2
Received:
Revised:
Online:
Published:
Contact:
Abstract: A pilot-plant test research was carried out by the process of coagulation-ultrafiltration-reverse osmosis to treat secondary effluent in Northeast General Pharmaceutical Factory. The results indicated that the removal efficiencies of turbidity and COD during the process of coagulation were more than 62.0% and 22.3% respectively. The removal efficiencies of turbidity and COD during the process of ultrafiltration were more than 87.4% and 54.5% respectively. And the desalting ratio during the process of reverse osmosis was more than 97.6%. The experimental results showed that the effluent’s quality of the process were satisfied and excelled to the quality index of circulation water, and the process operation was stable.
Key words: secondary effluent, coagulation, ultrafiltration, reverse osmosis
CLC Number:
LIU Feng,ZHANG Lan-ying,LIU Peng,LANG Xian-ming,YANG Nan,LIANG Shu-qing. Treatment of Secondary Effluent of Pharmaceutical Wastewater by Combination of Membrane Separation with Coagulation[J].J4, 2008, 38(3): 468-0472.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://xuebao.jlu.edu.cn/dxb/EN/
http://xuebao.jlu.edu.cn/dxb/EN/Y2008/V38/I3/468
Cited