Abstract: A simulation model was built for the thermodynamic system of the ground source heat pump (GSHP) based on the G-function theory of the underground heat exchanger (UGHE), and an analysis method for the long-term operation of the GSHP system was proposed. Taking the severe cold region as example, the system winter heating operation conditions in the last 3 years were studied. The fluid temperature variations at the inlet and the outlet of the UGHE, the coefficient of performance and the energy consumption of the heat pump and the system were analyzed simulationally and the results were compared with the measured data. The results show that the model and method are feasible, providing an effective approach for further forecast and analysis.

Key words: thermal engineering, ground source heat pump (GSHP), underground heat exchanger (UGHE), operation station

CLC Number: 

  • TK529
[1] Katarzyna Zwarycz. Snow melting and heating systems based on geothermal heat pumps at goleniow airport poland. Geothermal Training Programmer Reports, The United Nations University, Iceland, 2002.
[2] Gao Q, M Li, M Yu, et al. Review of development from GSHP to UTES in China and other countries[J]. Renewable and Sustainable Energy Reviews, 2009,13(6-7):1383-1394.
[3] 张信树,刘泽华,陈北领,等. 某写字楼地源热泵冬季供暖性能测试及节能分析[J]. 制冷空调与电力机械,2007,28(3):30-33. Zhang Xin-shu, Liu Ze-hua, Chen Bei-ling, et al. Heating performance test of the soil source heat pump in one office building in winter and analysis of its energy saving[J]. Refrigeration Air Conditioning & Electric Power Machinery,2007, 28(3):30-33.
[4] 江章宁,胡平放,雷飞,等. 地埋管地源热泵系统冬季运行测试研究[J].暖通空调,2009, 39(3):115-118. Jiang Zhang-ning, Hu Ping-fang, Lei Fei,et al. Measurement of operation of a GSHP system in winter[J]. Jounal of HV&AC, 2009, 39(3):115-118.
[5] 王华军,赵军,沈亮. 地源热泵系统长期运行特性的实验研究[J]. 华北电力大学学报,2007, 34(2):52-54. Wang Hua-jun, Zhao Jun, Shen Liang. Experimental investigation on long-term performance of ground source heat pump system [J]. Journal of North China Electric Power University,2007, 34(2):52-54.
[6] 赵军,王华军,宋著坤,等. U型管埋地换热器长期性能的实验研究与灰色预测[J]. 太阳能学报,2006,27(11):1137-1141. Zhao Jun, Wang Hua-jun, Song Zhu-kun, et al. Experimental and grey prediction on the long-term behavior of U-shaped ground coupled heat exchangers[J]. Acta Energiae Solaris Sinica, 2006,27(11):1137-1141.
[7] Spitler J D. GLHEPRO—a design tool for commercial building ground loop heat exchangers//Proceedings of the Fourth International Heat Pumps in Cold Climates Conference, Aylmer, Québec, 2000.
[8] Yavuzturk C, Spitler J D. A short time step response factor model for vertical ground loop heat exchangers[J]. ASHRAE Transactions, 1999,105(2):475-485.
[9] 齐子姝,高青,刘研,等.联供模式地下水换热器温度及其热泵效能分析[J].吉林大学学报:工学版,2012,42(2):339-343. Qi Zi-shu, Gao Qing, Liu Yan,et al. Analysis of temperature of underground heat exchanger and efficiency of heat pump with combined cooling and heating[J]. Journal of Jilin University(Engineering and Technology Edition),2012,42(2):339-343.
[10] Michopoulos A, Kyriakis N. Predicting the fluid temperature at the exit of the vertical ground heat exchangers[J]. Applied Energy,2009,86:2065-2070.
[1] XU Liang, LAN Jin, WANG Ming-sen, GAO Jian-min, LI Yun-long. Effect of swirl number on heat transfer characteristics of swirling impinging jets [J]. Journal of Jilin University(Engineering and Technology Edition), 2018, 48(5): 1483-1491.
[2] Su Jun-lin,Wang Zhen-kun,Jiao Zhen-wei . High efficiency and low pollution heating equipment with gasliquid
direct mix and phase change heat transfer
[J]. 吉林大学学报(工学版), 2008, 38(02): 278-0282.
[3] Cui Shuqin,Gao Qing,Li Ming,Jiang Yan. Underground heat transfer characteristics in discontinuous operation of GSHP and its control strategy [J]. 吉林大学学报(工学版), 2006, 36(02): 172-0176.
[4] SU Junlin, LU Jun, WANG Zhenkun. Heat Transfer Characteristics of Open Twophase Thermosyphon [J]. 吉林大学学报(工学版), 2005, 35(04): 368-372.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!