吉林大学学报(理学版) ›› 2026, Vol. 64 ›› Issue (2): 451-0457.

• • 上一篇    下一篇

尿酸人工抗原的合成及多克隆抗体的制备

郭红岩1, 孙美琪1, 崔百吉2, 王淑红3, 杨威龙2, 修志明1,2, 王志兵1   

  1. 1. 长春工业大学 化学与生命科学学院, 长春130012; 
    2.  吉林医药学院 吉林省抗体工程科技协同创新中心, 吉林 吉林132013; 
    3. 长春百纯和成医药科技有限公司, 长春 130012
  • 收稿日期:2024-12-25 出版日期:2026-03-26 发布日期:2026-03-26
  • 通讯作者: 修志明 E-mail: xiuzm10@mails.jlu.edu.cn

Synthesis of Uric Acid Artificial Antigen and Preparation of Polyclonal Antibodies

GUO Hongyan1, SUN Meiqi1, CUI Baiji2, WANG Shuhong3,  YANG Weilong2, XIU Zhiming1,2, WANG Zhibing1   

  1. 1.  College of Chemistry and Life Sciences,  Changchun University of Technology,  Changchun 130012,  China; 2.  Jilin Collaborative Innovation Center for Antibody Engineering,  Jilin Medical University,  Jilin 132013,  Jilin Province, China; 3. Changchun BC&HC Pharmaceutical Technology Co., Ltd., Changchun 130012,  China
  • Received:2024-12-25 Online:2026-03-26 Published:2026-03-26

摘要: 针对小分子尿酸不具备免疫原性、 难以用免疫法直接检测的问题, 将尿酸用琥珀酸酐修饰, 得到修饰后的尿酸半抗原, 再将尿酸半抗原与牛血清蛋白和卵清蛋白偶联制得尿酸人工抗原及包被抗原, 用尿酸人工抗原免疫小鼠, 制备得到尿酸多克隆抗体. 通过Fourier变换红外光谱法和质谱法对尿酸半抗原进行表征, 通过紫外分光光度法和聚丙烯酰胺凝胶电泳法对人工抗原及包被抗原进行表征, 通过间接竞争酶联免疫吸附实验(ELISA)测定抗体的效价、 灵敏度和特异性. 结果表明: 多抗血清的效价均在1∶25 600以上, 且1~4号小鼠抗体的灵敏度分别为10.337,8.426,16.457,21.177 μg/mL; 该抗体与尿酸的结构类似物的交叉反应率均小于1% . 可见, 该实验免疫制备的尿酸多克隆抗体获得了较高的效价、 较高的灵敏度及较强的特异性, 为尿酸的免疫检测提供了实验依据. 

关键词:  , 尿酸, 半抗原, 人工抗原, 多克隆抗体

Abstract: Aiming at the problem that the small molecule uric acid lacked immunogenicity and it was difficult to directly detect it using immunological methods, we modified uric acid with succinic anhydride to obtain a modified uric acid hapten, and then conjugated the uric acid hapten with bovine serum albumin and ovalbumin to prepare uric acid artificial antigens and coating antigens. We immunized mice with uric acid artificial antigens to prepare uric acid polyclonal antibodies. Uric acid hapten was characterized by Fourier transform infrared spectroscopy and mass spectrometry, artificial antigen and coating antigen were characterized by ultraviolet spectrophotometry and polyacrylamide gel electrophoresis, and antibody titer, sensitivity and specificity were determined by indirect competitive enzyme-linked immunosorbent assay (ELISA). The results show that the titers of the multi antibody serum are all above 1∶25 600, and the sensitivities of the antibodies in mice 1—4 are 10.337,8.426,16.457,21.177 μg/mL, respectively. The cross reactivity rates between the antibodies and structural analogues of uric acid are all less than 1%. It can be seen that the uric acid polyclonal antibody prepared by immunization in this experiment has achieved high potency, high sensitivity, and strong specificity, providing experimental basis for the immunological detection of uric acid. 

Key words: uric acid, hapten, artificial antigen, polyclonal antibody

中图分类号: 

  • R392