Abstract: A convenient and fast numerical calculation method of alltime apparent resistivity for the transient electromagnetic method-inverse spline interpolation method has been developed. Several conversion examples, from induced electromotive force through centralloop TEM2.5D forward program to apparent resistivity, illustrate the feasibleness of inverse spline method. At the same time, the method has also laid the foundations of initial model definition in TEM automatic inversion.

Key words: transient electromagnetic method, alltime apparent resistivity, inverse spline interpolation

CLC Number: 

  • P631.325
[1] Yang Haiyan, Yue Jianhua, Xu Zhengyu, Zhang Hua, Jiang Zhihai. Transient Electromagnetic Method Modeling in Ground-Borehole Model with Overburden Influence [J]. Journal of Jilin University(Earth Science Edition), 2016, 46(5): 1527-1537.
[2] Yang Haiyan, Deng Juzhi, Tang Hongzhi, Lin Yun. Translation Algorithm of Data Interpretation Technique in Full-Space Transient Electromagnetic Method [J]. Journal of Jilin University(Earth Science Edition), 2014, 44(3): 1012-1017.
[3] HAN Jiang-tao,LIU Guo-xing,TANG Jun-hui. Application of Transient Electromagnetic Pseudo-Seismic Interpretation Imaging Method to Explore Permafrost Strata in Mohe Region [J]. J4, 2008, 38(6): 1060-1064.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!