吉林大学学报(工学版) ›› 2013, Vol. 43 ›› Issue (增刊1): 291-294.

Previous Articles     Next Articles

Research of comfort disparity range in 3D contents

CHEN Zai-qing, SHI Jun-sheng, TAI Yong-hang   

  1. Color & Image Vision Lab., Yunnan Normal University, Kunming 650092, China
  • Received:2012-09-16 Published:2013-06-01

Abstract:

In order to understand the underlying causes of visual discomfort so that it can be minimized or even eliminated,it is very essential to evaluate the visual comfort of 3D displays.The visual comfort is highly correlated with the disparity information of 3D contents.Hence,a subjective evaluation experiment was carried out to measure visual comfort of stereoscopic video at different disparity levels.Results show that the degree of visual comfort decreases as disparity increases and the comfort disparity is in the range of -119 to +115 minute of arc.

Key words: 3D contents, visual comfort, binocular disparity, subjective

CLC Number: 

  • TP751

[1] Pking W M.Viewing comfort with stereoscopic pictures:An experimental study on the subjective effects of disparity magnitude and depth of focus [J].Journal of the Society for Information Display,1995,3(3)101-103.

[2] Yano S,Emoto M,Mitsuhashi T.Two factors in visual fatigue caused by stereoscopic HDTV images [J].Displays,2004,25(4):141-50.

[3] Nojiri Y,Yamanoue H,Hanazato A,et al.Visual comfort/discomfort and visual fatigue caused by stereoscopic HDTV viewing[C]//Proc.SPIE 5291,2004:303-313.

[4] Speranza F,Tam W J,Renaud R,et al.Effect of disparity and motion on visual comfort of stereoscopic images[C]//Proc.SPIE 6055,2006:1-10.

[5] Lambooij M,Ijsselsteijn W,Fortuin M,et al.Visual discomfort and visual fatigue of stereoscopic displays:a review [J].Journal of Imaging Science and Technology,2009,53(3):1-14.

[6] Meesters L,Ijsselsteijn W,Seuntiens P.A survey of perceptual evaluations and requirements of three-dimensional TV [J].IEEE Transactions on Circuits and Systems for Video Technology,2004,14(3):381-91.

[7] 郑华东,于瀛洁,程维明.三维立体显示技术研究新进展 [J].光学技术,2008,34(3):426-430.Zheng Hua-dong,Yu Ying-jie,Cheng Wei-ming.Areview on three-dimensional display techniques[J].Optical Technique,2008,34(3):426-430.

[8] Jung Y J,Sohn H,Lee S,et al.Quantitative measurement of binocular color fusion limit for non-spectral colors [J].Optics Express,2011,19(8):25-38.

[9] Mendiburu B.3D movie making:stereoscopic digital cinema from script to screen [M].Focal Press,2009.

[10] Tam W J,Speranza F,Yano S,et al.Stereoscopic 3D-TV:visual comfort [J].Broadcasting IEEE Transactions on,2011,57(2):335-346.

[11] Ukai K,Howarth PA.Visual fatigue caused by viewing stereoscopic motion images:Background,theories,and observations [J].Displays,2008,29(2):106-116.

[12] Hoffman D M,Girshick A R,Akeley K,et al.Vergence-accommodation conflicts hinder visual performance and cause visual fatigue [J].Journal of Vision,2008,8(3):1-30,33.

[13] Kooi FL,Toet A.Visual comfort of binocular and 3D displays [J].Displays,2004,25(3):99-108.

[14] Speranza F,Wilcox L M.Viewing stereoscopic images comfortably:the effects of whole-field vertical disparity [C]//Proc.SPIE 4660,2002:18-25.

[15] Allison R S.Analysis of the influence of vertical disparities arising in toed-in stereoscopic cameras [J].Journal of Imaging Science and Technology,2007,51(4):317-327.

[16] Nojiri Y,Yamanoue H,Hanazato A,et al.Measurement of parallax distribution and its application to the analysis of visual comfort for stereoscopic HDTV [C]//Proc.SPIE 5006,2003:195-205.

[17] Nojiri Y,Yamanoue H,Ide S,et al.Parallax distribution and visual comfort on stereoscopic HDTV[C]//Proceedings of the Proc IBC,F,2006:8-16.

[18] ITU.Guidelines on metrics to be used when tailoring television programmes to broadcasting applications at various image quality levels [M].Display Sizes and Aspect Ratios ITU-R Rec BT1845-1,2010.

[19] WMA.Ethical principles for medical research involving human subjects [M].Declaration of Helsinki,2009.

[20] ITU-R.Methodology for the subjective assessment of the quality of television pictures [M].ITU-R Recommendation BT500.1974-2004.

[21] ITU-R.Subjective assessment of stereoscopic television pictures [M].ITU-R Recommendation BT1438,2000,

[22] ITU-R.Methodology for the subjective assessment of the quality of television pictures [J].ITU-R Recommendation BT500-10,2010,42(6):10-17.

[23] Tam C V,Speranza.Surrogate depth maps for stereoscopic imaging:Different edges types [C]// Proc.SPIE 6490,2007:1-9.

[24] Lambooij M,Ijsselsteijn W,Heynderickx I.Visual discomfort of 3D TV:Assessment methods and modeling [J].Displays,2011,32(4):209-218.

[25] Sheedy J E,Hayes J.Is all asthenopia the same [J].Optometry & Vision Science,2003,80(11):732-739.

[26] Emoto M,Niida T,Okano F.Repeated vergence adaptation causes the decline of visual functions in watching stereoscopic television [J].Journal of Display Technology,2005,1(2):328-340.

[27] Emoto M,Nojiri Y,Okano F.Changes in fusional vergence limit and its hysteresis after viewing stereoscopic TV [J].Displays,2004,25(2-3):67-76.

[28] Kuze J,Ukai K.Subjective evaluation of visual fatigue caused by motion images [J].Displays,2008,29(2):159-166.

[29] Kennedy R S,Lane N E,Berbaum K S,et al.Simulator sickness questionnaire:An enhanced method for quantifying simulator sickness [J].International Journal of Aviation Psychology,1993,3(3):203-220.

[30] Meesters L M J,Ijsselsteijn W A,Seunti N S Pjh.A survey of perceptual evaluations and requirements of three-dimensional TV [J].Circuits and Systems for Video Technology IEEE Transactions on,2004,14(3):381-391.

[1] SU Li-li, WANG Deng-feng, CHEN Shu-ming, JIANG Ji-guang, WANG Qian. Subjective evaluation test of influence of color on vehicle interior sound quality [J]. , 2012, (03): 539-544.
[2] SU Li-li, WANG Deng-feng, JIANG Ji-guang, CHEN Shu-ming, TAN Gang-ping. Fuzzy comprehensive evaluation of vehicle interior sound quality based on semantic differential method [J]. 吉林大学学报(工学版), 2012, 42(02): 309-315.
[3] GAO Yin-Han, SUN Qiang, LIANG Jie, TANG Rong-Jiang. Evaluation method and mathematical model of vehicle interior sound quality during acceleration [J]. 吉林大学学报(工学版), 2010, 40(06): 1502-1506.
[4] LIANG Jie,XIE Jun,GAO Yin-han,SUN Qiang. Vehicle interior sound quality preference evaluation model based on correlation analysis [J]. 吉林大学学报(工学版), 2009, 39(增刊2): 274-0278.
[5] Shi Guo-biao,Zhang Xin,Lin Yi . Subjective fuzzy evaluation of steering feel for electric power steering system [J]. 吉林大学学报(工学版), 2007, 37(04): 751-755.
[6] Wang Deng-feng, Liu Zong-wei, Liang Jie, Wang Shi-gang, Jiang Ji-guang . Subjective evaluation test and objective quantificational description of vehicle interior noise quality
[J]. 吉林大学学报(工学版), 2006, 36(增刊2): 41-45.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!