J4 ›› 2011, Vol. 49 ›› Issue (05): 932-934.

Previous Articles     Next Articles

 Dose Distribution of 125I |Source in Water by Means of Monte Carlo Simulation

MEI Xue song1, ZHANG Hui1, MA Yu gang2, ZHAO Guang yi2, ZHOU Wei1, PANG Yang1, GUAN Shi rong1, WANG Xue hang3   

  1. 1. Institute of Technical Physics, |Heilongjiang Academy of Science, Harbin 150086, China|2. College of Physics, Jilin University, Changchun 130012, China;3. Health Inspection of Heilongjiang, Harbin 150001, China
  • Received:2010-11-17 Online:2011-09-26 Published:2011-09-27
  • Contact: ZHANG Hui E-mail:jluzhanghui@163.com

Abstract:

The dose distribution of 125I source in water was studied by means of Monte Carlo simulations and thermo luminescent dosemeter (TLD) method, and the results were compared. The results show that when 125I source activity was 1.37×107 Bq, the radial distances of 125I source were 0.5,1.0,1.5 and 2 cm, the dose rates of 125I with MCNP method were 11.7,3.3,1.5,0.8 mGy/h, TLD  measurements were 12.2,3.1,1.3,0.7 mGy/h;  125I source radial dose rate decreased rapidly with increasing distance.

Key words: Monte Carlo code for neutron and particle, dose rate, thermo luminescent dosemeter, 125I source

CLC Number: 

  • O571.3