J4

• 环境科学 • Previous Articles     Next Articles

Simultaneous Determination of Malathion and Atrazine in Waterby High Performance Liquid Chromatography

WANG Ao1,2, GAO Qian1, WANG Xiaoli1, XU Zili1, LI Yu1,3   

  1. 1. College of Environment and Resources, Jilin University, Changchun 130061, China;2. Jilin Provincial Center for Sanitary Inspection and Test, Changchun 130062, China;3. Energy and Environmental Research Center, North China Electric Power University, Beijing 102206, China
  • Received:2007-03-30 Revised:1900-01-01 Online:2008-01-26 Published:2008-01-26
  • Contact: LI Yu

Abstract: Simultaneous determination of malathion and atrazine by HPLC was carried out under the following laboratory conditions: the optimum detecting wave length 220 nm, and mobile phase V(CH3OH)∶V(H2O)=7∶3, which could reach better separating result. The linearity ranges for malathion and atrazine were 0.003 66~1.83 μmol/Land 0.121~60.3 μmol/L, respectively, the linearity correlation coefficients for malathion and atrazine were both more than 0.999 4. The detection limits for the two pesticides were 0.003 66 μmol/L and 0.121 μmol/L, respectively. The RSDs of the method for determining malathion and atrazine were lower than 10%.

Key words: malathion, atrazine, high performance liquid chromatog raphy, aquatic environmental monitoring

CLC Number: 

  • X132