J4 ›› 2009, Vol. 35 ›› Issue (6): 1079-1083.

• 基础研究 • 上一篇    下一篇

自体肺体外循环对肺功能的保护作用

林柏松|张秀和|张柏民|姜亦忠|李哲|孙耀*   

  1. 吉林大学中日联谊医院心脏外科|吉林 长春 130033
  • 收稿日期:2009-08-31 出版日期:2009-11-28 发布日期:2009-12-15
  • 通讯作者: 李哲 E-mail:yisheng999@hotmail.com
  • 作者简介:林柏松(1969-)|男|吉林省长春市人|医学博士|副教授|主要从事心肌保护和肺保护方面的研究。
  • 基金资助:

     吉林省科技厅科技发展计划项目资助课题(20080742)

 Protective effect of extracorporeal circulation with autologous lung as oxygenator on lung function

 LIN Bai-Song, ZHANG Xiu-He, ZHANG Bai-Min, JIANG Yi-Zhong, LI Zhe, SUN Yao*   

  1. Department of Cardiovascular Surgery,China-Japan Union Hospital,Jilin University,Changchun 130033,China
  • Received:2009-08-31 Online:2009-11-28 Published:2009-12-15

摘要:

目的:探讨以自体肺取代人工肺的体外循环(CPB)方法对犬肺功能的保护效果。方法: 12 只杂种犬随机分为对照组及实验组(每组6只)。对照组在CPB期间使用膜式氧合器,实验组在CPB期间使用自体肺进行氧合,两组均阻断主动脉90 min、辅助循环30min, CPB前及停止后15及60 min监测气道峰压、肺血管阻力和肺静脉血氧分压,留取血标本进行生化分析,对肺组织进行光、电镜观察。结果:CPB后15和60 min,对照组气道阻力明显高于CPB前(P<0.05),实验组与CPB前比较差异无显著性(P>0.05),实验组CPB后15和60 min均低于对照组(P<0.05);CPB后15和60 min各组肺血管阻力均明显高于CPB前(P<0.01),实验组明显低于对照组相应时间点(P<0.01);CPB后15和60 min各组氧指数均明显高于CPB前(P<0.01),实验组明显低于对照组相应时间点(P<0.01);实验组CPB后60 min 肺泡-动脉氧压力差(P[A-a]O2)明显低于对照组(P<0.001)。实验组肺组织MDA含量及支气管肺泡灌洗液(PAL)中性粒细胞计数明显低于对照组(P<0.001,P<0.05)。实验组组织学改变明显轻于对照组(P<0.001)。结论: CPB后肺脏形态和功能有明显变化,自体肺体外循环对犬肺形态和功能有良好的保护作用。

关键词: 自体肺;肺保护;体外循环

Abstract:

Objective
 To determine the protective effect of extracorporeal circulation with autologous lung as oxygenator to lung function in dogs.Methods Twelve adult mongrel dogs were randomly divided into control group and experimental group.Cardiopulmonary bypass (CPB) using a membrane oxygenator (control group) or using the autologous lung (experimental group) for gas exchange was performed for 120 min in an alternating series of 12 mongrel dogs with the heart arrested for 90 min by crystalloid cardioplegia and 30 min reperfusion.Malondialdehyde (MDA) of lung tissue,alveolar-arterial oxygen gradient (P[A-a]O2),the ratio of white blood cells in BALf and lung function were measured at different time points (before CPB, 15 and 60 min after CPB),lung biopsies were also made. Results The levels of airway resistance at  15 and 60 min after CPB in control group were higher than the airway resistance levels before CPB (P<0.05).The levels of airway resistance at  15 and 60 min after CPB in experimental group  were lower than those in control group at the same points (P<0.01).The levels of pulmonary vascular resistance at 15 and 60 min after CPB in each group were lower than the levels before CPB (P<0.01).The level at  15 and 60 min after CPB in control group  was higher than that  in experimental group  at the same points(P<0.05).The levels of PaO2/FiO2 at  15 and 60 min after CPB in each group were higher than the levels before CPB (P<0.01).The levels of PaO2/FiO2 at  15 and 60 min after CPB in control group   were lower than those  in experimental  group at the same points(P<0.05).The levels of P[A-a]O2 at  60 min after CPB in experimental group  were lower than those  in control group(P<0.001).The levels of MDA and neutrophil percentage in BALF at  90 min after CPB in  experimental group were lower than those 
 in control group (P<0.001,P<0.05).Morphological analysis revealed that  in  experimental group the  percentage of pathological lesions and alveolar hemorrhage grade values was lower than those in control group (P<0.001).
Conclusion Morphous and function have obvious changes in lungs after CPB.Extracorporeal circulation with autologous lung as oxygenator has  protective effect on  pulmonary morphous and function.

Key words: autologous lung;cardiopulmonary bypass;lung injury

中图分类号: 

  • R-332