[1] Brånemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw.Experience from a 10-year period[J].Scand J Plast Reconstr SurgSuppl, 1977,16:1-132.
[2] Klineberg I, Calford MB, Dreher B, et al.A consensus statement on osseoperception[J].Clin Exp Pharmacol Physiol, 2005,32(1/2):145-146.
[3] Bhatnagar VM, Karani JT, Khanna A, et al.Osseoperception:An implant mediated sensory motor control-A review[J].J Clin Diagn Res, 2015,9(9):ZE18-20.
[4] Jacobs R, van Steenberghe D.From osseoperception to implant-mediated sensory-motor interactions and related clinical implications[J].J Oral Rehabil, 2006,33(4):282-292.
[5] Hita-Carrillo C, Hernández-Aliaga M, Calvo-Guirado JL.Tooth-implant connection:a bibliographic review[J].Med Oral Patol Oral Cir Bucal, 2010,15(2):e387-e394.
[6] Johnson EO, Zoubos AB, Soucacos PN.Regeneration and repair of peripheral nerves[J].Injury,2005,36 (4):S24-S29.
[7] Variot G, Remy C.Sur les nerfs de la moelle des os[J]. J Anat Physiol, 1880,16 (Suppl):273-284.
[8] Bjurholm A.Neuroendocrine peptides in bone[J].Int Orthop, 1991,15(4):325-329.
[9] Heasman PA.The myelinated fibre content of human inferior alveolar nerves from dentate and edentulous subjects[J].J Dent, 1984,12(4):283-286.
[10] Weiner S, Klein M, Doyle JL, et al.Identification of axons in the peri-implant region by immunohistochemistry[J].Int J Oral Maxillofac Implants,1995,10(6):689-695.
[11] Wada S, Kojo T, Wang YH, et al.Effect of loading on the development of nerve fibers around oral implants in the dog mandible[J].Clin Oral Implants Res,2001, 12(3):219-224.
[12] Corpas Ldos S, Lambrichts I, Quirynen M, et al.Peri-implant bone innervation:histological findings in humans[J].Eur J Oral Implantol, 2014,7(3):283-292.
[13] Henry PJ.Oral implant restoration for enhanced oral function[J].Clin Exp Pharmacol Physiol, 2005,32(1/2):123-127.
[14] Batista M, Bonachela W, Soares J.Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses[J].Clin Oral Implants Res, 2008,19(6):565-569.
[15] Sakada S.Mechanoreceptors in fascia, periosteum and periodontal ligament[J].Bull Tokyo Med Dent Univ, 1974,21(Suppl):11-13.
[16] van Loven K, Jacobs R, Swinnen A, et al.Sensations and trigeminal somatosensory-evoked potentials elicited by electrical stimulation of endosseous oral implants in humans[J].Arch Oral Biol, 2000,45(12):1083-1090.
[17] Jacobs R, van Steenberghe D.Comparison between implant-supported prostheses and teeth regarding passive threshold level[J].Int J Oral Maxillofac Implants, 1993,8(5):549-554.
[18] Klineberg I, Murray G.Osseoperception:sensory function and proprioception[J].Adv Dent Res, 1999,13:120-129.
[19] Ysander M, Branemark R, Olmarker K, et al.Intramedullary osseointegration:development of a rodent model and study of histology and neuropeptide changes around titanium implants[J].J Rehabil Res Dev, 2001,38(2):183-190.
[20] Qiao SC, Lv XF, Zhuang LF, et al.Animal study of sensory function of nerve fibers surrounding dental implant[J].Shanghai J Stomatol, 2011,20(2):119-124.
[21] Eliav E, Gracely RH.Sensory changes in the territory of the lingual and inferior alveolar nerves following lower third molar extraction[J].Pain, 1998,77(2):191-199.
[22] Yan C, Ye L, Zhen J, et al.Neuroplasticity of edentulous patients with implant-supported full dentures[J].Eur J Oral Sci, 2008,116(5):387-393.
[23] Habre-Hallage P, Hermoye L, Gradkowski W, et al.A manually controlled new device for punctuate mechanical stimulation of teeth during functional magnetic resonance imaging studies[J].J Clin Periodontol, 2010, 37(9):863-872.
[24] Habre-Hallage P, Dricot L, Jacobs R, et al.Brain plasticity and cortical correlates of osseoperception revealed by punctate mechanical stimulation of osseointegrated oral implants during fMRI[J].Eur J Oral Implantol, 2012, 5(2):175-190.
[25] Grieznis L, Apse P, Blumfelds L.Passive tactile sensibility of teeth and osseointegrated dental implants in the maxilla[J].Stomatologija, 2010,12(3):80-86.
[26] Kazemi M, Geramipanah F, Negahdari R, et al.Active tactile sensibility of single-tooth implants versus natural dentition:a split-mouth double-blind randomized clinical trial[J].Clin Implant Dent Relat Res, 2014,16(6):947-955.
[27] Yuan Q, Gong P, Tan Z.Schwann cell graft:a method to promote sensory responses of osseointegrated implants[J].Hypotheses, 2007,69(4):800-803.
[28] Madduri S, Gander B.Schwann cell delivery of neurotrophic factors for peripheral nerve regeneration [J].J Peripher Nerv Syst, 2010, 15(2):93-103.
[29] Yu H, Liu J, Ma J, et al.Local delivery of controlled released nerve growth factor promotes sciatic nerve regeneration after crush injury[J].Neurosci Lett, 2014, 566:177-181.
[30] Lee JY, Kim SM, Kim MJ, et al.Controlled release of nerve growth factor from heparin-conjugated fibrin gel within the nerve growth factor-delivering implant[J].J Korean Assoc Oral Maxillofac Surg, 2014, 40(1):3-10.
[31] Qin J, Wang L, Sun Y, et al.Concentrated growth factor increases Schwann cell proliferation and neurotrophic factor secretion and promotes functional nerve recovery in vivo [J].Int J Mol Med, 2016, 37(2):493-500.
[32] Qin J, Wang L,Zheng L, et al.Concentrated growth factor promotes Schwann cell migration partly through the integrin β1-mediated activation of the focal adhesion kinase pathway [J].Int J Mol Med, 2016, 37(5):1363-1370.
[33] Ma L, Xiang L, Yao Y, et al.CGRP-alpha application:a potential treatment to improve osseoperception of endosseous dental implants[J].Med Hypotheses, 2013,81(2):297-299.
[34] 孙琳琳.牙种植修复方式对种植体周神经纤维再生及骨组织改建的影响[D].大连:大连医科大学,2013.
[35] Zhu YB, Lin Y, Qiu LX, et al.An animal study of peripheral neurophysiologic mechanism in osseoperception phenomena of dental implant[J].Zhonghua Kou Qiang Yi Xue Za Zhi, 2009,44(8):460-463.
[36] Huang Y, van Dessel J, Martens W, et al.Sensory innervation around immediately vs.delayed loaded implants:a pilot study[J].Int J Oral Sci, 2015,7(1):49-55.
[37] Clarke JC, Tuft BW, Clinger JD, et al.Micropatterned methacrylate polymers direct spiral ganglion neurite and Schwann cell growth[J].Hear Res, 2011,278(1/2):96-105.
[38] Yuan Q, Liao D, Yang X, et al.Effect of implant surface microtopography on proliferation, neurotrophin secretion, and gene expression of Schwann cells[J].J Biomed Mater Res A, 2010, 93(1):381-388.
[39] Li X, Liao D, Gong P, et al.Biological behavior of neurally differentiated periodontal ligament stem cells on different titanium implant surfaces[J].J Biomed Mater Res A, 2014, 102(8):2805-2812.
[40] Yin CC, Li BC, Wang HL, et al.Biological behaviors of RSC96 cells and dorsal root ganglion neurons on different titanium surface topographies[J].J Biomater Tissue Eng, 2016,6(12):967-974.
[41] 李保胜.不同种植体表面形貌对神经再生影响的初步研究[D].长春:吉林大学, 2013.
[42] Enkling N, Utz KH, Bayer S, et al.Osseoperception:active tactile sensibility of osseointegrated dental implants[J].Int J Oral Maxillofac Implants, 2010, 25(6):1159-1167. |