J4 ›› 2010, Vol. 36 ›› Issue (6): 1186-1188.

Previous Articles     Next Articles


Determination of emodin in Gengnianan capsule by HPLC


HOU Yi1,YIN Jian-yuan2,LI Hong-bin3,LI Yan-yan2,ZHANG Ying2,LI Wei2,MENG Qing-wen4,MENG Qin5   

  1. 1. Department of Tissue Engineering,School of Pharmacy,Jilin University,Changchun 130021,China;2.Department of Natural Medicinal Chemistry,School of Pharmacy,Jilin University,Changchun 130021,China;3. Xinmin Chemical Center,School of Chemistry,Jilin University,Changchun 130021,China;4. High School Attached to Northeast Normal University,Changchun 130021,China;5. Pharmacy Experimental Center,School of Pharmacy,Jilin University,Changchun 130021,China
  • Received:2010-05-21 Online:2010-11-28 Published:2010-11-28

Abstract:

Objective To establish the high performane liqnid chromatography (HPLC)   for determining emodin in Gengnianan capsule,and provide the basis for the quality control of industrial production.Methods The HPLC was developed to determine the emodin in Gengnianan capsule.The developed conditions of HPLC were as follows: the Shimpack VP-ODS C18(150 mm×4.6mm,5 μm), methanol-0.1% phosphoric acid solution(77:23) as mobile phase,the detection wavelength of  254 nm,and the column temperature of 40℃.Results The linear range of emodin was 0.04-0.32 μg,the regression equation was Y=1060+2513102X,r=0.9991.The average recovery was 98.6%,and the RSD was 1.88% (n=6).The RSD in accuracy,stability and repeatability test were 0.86%,2.33% and 1.88%,respectively.Conclusion This method is accurate,simple and reliable,which provide the scientific basis for the quality control of Gengnianan capsule.

Key words: Gengnianan capsul;emodin;high performance liquid chromatography

CLC Number: 

  •