Establishment of TMJ defect models and evaluation on repair effect of CFR-PEEK material artificial joint in rabbits

HAN Minglin1, LI Minghe1, JI Xin2, HAN Ruyu3, ZHANG Ning1, CUI Leihua1, SUN Lanfang1, HAN Chengmin1   

  1. 1. Department of Oral and Maxillofacial Surgery, Stomatology Hospital, Jilin University, Changchun 130021, China;
    2. Department of Sterilization and Supply Center, Stomatology Hospital, Jilin University, Changchun 130021, China;
    3. Department of Orthodontics, Stomatology Hospital, Jilin University, Changchun 130021, China
  • Received:2017-03-19 Online:2017-09-28 Published:2017-09-29

摘要: 目的:探讨兔颞下颌关节(TMJ)关节突缺损模型建立后实现关节置换的方法,阐明碳纤维增强型聚醚醚酮(CFR-PEEK)材料制作的TMJ假体的置换修复效果,为临床应用CFR-PEEK人造关节置换TMJ提供实验依据。方法:13只健康成年日本大耳白兔按照随机数字法分为实验组(n=6)、阳性对照组(n=4)和阴性对照组(n=3)。实验组兔切除右侧TMJ关节突,建立关节缺损模型,同期植入CFR-PEEK人造关节;阳性对照组兔切除右侧TMJ关节突,建立关节缺损模型,不植入CFR-PEEK人造关节;阴性对照组兔不做任何处理。通过CT影像学检查评估人造关节植入后的固位和替代修复效果。连续记录13周各组兔体质量并进行比较。结果:建立的兔TMJ关节突缺损模型能够成功植入CFR-PEEK人造关节。CT影像学检查,经三维重建和体外显影处理后可见植入CFR-PEEK人工关节固位良好,代替正常关节发挥作用;13周兔体质量观察,与阳性对照组比较,实验组兔体质量增加(P < 0.05);实验组和阴性对照组兔体质量均明显增加,但2组比较差异无统计学意义(P > 0.05)。实验组和阴性对照组兔体质量均正常增长,阳性对照组兔体质量增长较为缓慢,甚至停止增长或者负增长。结论:植入CFR-PEEK人造关节修复关节突缺损能够有效恢复兔正常咀嚼功能,CFR-PEEK人造关节成功应用于TMJ缺损修复,有望成为一种重建TMJ关节突的理想材料。

关键词: 缺损, 碳纤维增强型聚醚醚酮材料, 人造关节, 颞下颌关节

Abstract: Objective: To investigate the method of arthroplasty for reconstructing femporomandibular joint(TMJ) after the establishment of TMJ articular defect models in the rabbits, and to clarify the replacement and repair effects of carbon fiber reinforced polyetheretherketone (CFR-PEEK) material TMJ prostheses, and to provide an experimental basis for the clinical application of CFR-PEEK artificial joints to replace TMJ. Methods: Thirteen healthy adult Japanese rabbits were randomly divided into experimental group (n=6), positive control group (n=4) and negative control group (n=3). The right TMJ articular process of the rabbits in experimental group were resected to establish the joint defect models, and then the CFR-PEEK artificial joints were impanted. The right TMJ articular process of the rabbits in positive control group were resected, and the joint defect models were established without the CFR-PEEK artificial joint implantation. The rabbits in negative control group didn't receive any treatment.The body weights of the rabbits in each group were measured in 13 weeks. The effects of fixation and replacement after artificial joint implantation were assessed by CT imaging. Results: The TMJ articular process defect model was successfully implanted with the CFR-PEEK artificial joint. The CT imaging results after three-dimensional reconstruction and CT images by contrast in vitro showed that the CFR-PEEK-implanted artificial joint was fixed well, it could be instead of the normal joint function.Compared with positive control group, the weights of rabbits in experimental group were significantly increased(P<0.05) at 13 weeks; compared with positive control group, the weights of rabbits in experimental group and negative control group were both significantly increased (P>0.05) at 13 weeks,but there was no significant difference between them(P>0.05).The weights of rabbits in experimental group and negative control group kept normal growth; the weights of rabbits in positive control group was increased slowly, and even stopped growing or was negative. Conclusion: The CFR-PEEK artificial joint can be successfully implanted into the TMJ defect model and be used to repair the defect which help to restore chewing function. The CFR-PEEK is expected to be an ideal material for reconstructing TMJ.

Key words: temporomandibular joints, defection, artificial joints, carbon fiber reinforced polyetheretherketone