吉林大学学报(医学版) ›› 2016, Vol. 42 ›› Issue (06): 1211-1214.doi: 10.13481/j.1671-587x.20160632

• 临床医学 • 上一篇    下一篇

新型混合融合技术治疗成人退变性脊柱侧凸的疗效及安全性评价

郭朝阳, 张树芳, 丁美兰   

  1. 江西省赣州市人民医院脊柱外科, 江西 赣州 341000
  • 收稿日期:2015-07-29 出版日期:2016-11-28 发布日期:2016-12-02
  • 通讯作者: 郭朝阳,副主任医师(Tel:0797-8083520,E-mail:13970106116@163.com) E-mail:13970106116@163.com
  • 作者简介:郭朝阳(1972-),男,江西省赣州市人,副主任医师,主要从事脊柱外科方面的研究。
  • 基金资助:

    江西省卫计委科研项目资助课题(20157172)

Therapeutic effect of new hybrid fusion technology in treatment of adult degenerative scoliosis and its safety evaluation

GUO Zhaoyang, ZHANG Shufang, DING Meilan   

  1. Department of Spine Surgery, Ganzhou People's Hospital, Jiangxi Province, Ganzhou 341000, China
  • Received:2015-07-29 Online:2016-11-28 Published:2016-12-02

摘要:

目的:观察新型混合融合技术治疗成人退变性脊柱侧凸(ADS)的疗效、安全性和依从性,为其临床应用提供依据。方法:选取本院50例ADS患者分为观察组和对照组。观察组25例患者采用新型混合融合技术进行治疗,对照组25例患者采用传统开放手术进行治疗。比较2组患者的手术时间、术中出血量、手术依从率、并发症发生率、腰椎功能改善率和植骨融合率。结果:观察组患者手术时间短于对照组(t=6.199,P=0.000),术中出血量少于对照组(t=6.242,P=0.000);2组患者临床总有效率比较差异无统计学意义(χ2=0.758,P=0.384);观察组患者术后并发症发生率低于对照组(χ2=4.667,P=0.031);观察组患者手术依从率高于对照组(χ2=5.357,P=0.021);治疗后1和3个月2组患者腰椎功能改善率和植骨愈合率比较差异均无统计学意义(χ2=1.471,P=0.225;χ2=0.725,P=0.395;χ2=1.587,P=0.208;χ2=0.739,P=0.390),治疗后6和12个月2组患者上述2项指标均高于对照组(χ2=4.500,P=0.034;χ2=4.667,P=0.031;χ2=5.357,P=0.021;χ2=7.018,P=0.008)。结论:新型混合融合技术治疗ADS具有安全性高、依从性好、手术时间短和术中出血量少等优势,适合临床推广。

关键词: 新型混合融合技术, 成人退变性脊柱侧凸, 传统开放手术, 安全性, 疗效

Abstract:

Objective: To observe the efficacy,security,and compliance of new hybrid fusion technology in the treatment of adult degenerative scoliosis (ADS),and to provide the basis for its clinical application.Methods: A total of 50 cases of ADS patients were divided into observation group(n=25) and control group(n=25).The patients in observation group were treated with new hybrid fusion technology,and the patients in control group were treated with traditional open surgery. The operation time,blood loss during the operation,surgical adherence,incidence of complications,improvement rate of lumbar function and fusion rate of bone graft of the patients in two groups were compared.Results: The operation time of patients in observation group was shorter than that in control group (t=6.199,P=6.199); the blood loss during the operation was less than that in control group (t=6.242,P=6.242). The total clinical effective rates of the patients in two groups had no statistically significant difference (χ2=0.758,P=0.758).The incidence of complications of the patients in observation group was lower than that those in control group (χ2=4.667,P=4.667), but the compliance rate were higher than that in control group (χ2=5.357,P=5.357).After treated for 1 and 3 months, the improvement rates of lumbar function and fusion rates of bone graft of the patients in two groups had no statistically significant differences (χ2=1.471,P=0.225; χ2=0.725,P=0.395; χ2=1.587,P=0.208; χ2=0.739,P=0.390);after treated for 6 and 12 months,the above data of the patients in observation group were higher than those in control group (χ2=4.500,P=0.034; χ2=4.667,P=0.031; χ2=5.357,P=0.021; χ2=7.018,P=0.008).Conclusion: New hybrid fusion technology used in ADS treatment has high security,good adherence,shorter operation time,less blood loss and other advantages, and it is suitable for clinical promotion.

Key words: new hybrid fusion technology, adult degenerative scoliosis, traditional open surgery, security, effect

中图分类号: 

  • R682.13