吉林大学学报(医学版) ›› 2013, Vol. 39 ›› Issue (1): 156-160.doi: 10.7694/jldxyxb20130135

• 影像学 • 上一篇    下一篇

超声造影技术对糖尿病肾病患者早期肾功能改变的评估及其临床意义

过新民1,2,金 泓2,潘丽雯2,陈 辉2,刘 薇2,全显跃1   

  1. 1.南方医科大学珠江医院影像诊断科,广东 广州 510280;2.暨南大学第四附属医院超声诊断科,广东 广州 510220
  • 收稿日期:2012-09-03 出版日期:2013-01-28 发布日期:2013-01-30
  • 通讯作者: 全显跃(Tel:020-61643460,E-mail:quanxianyue@163.com) E-mail:quanxianyue@163.com
  • 作者简介:过新民(1974-),男,江西省进贤县人,副主任医师,在读医学博士,主要从事超声诊断与介入研究。
  • 基金资助:

    广东省科技厅科技计划项目资助课题(201073)

Evaluation on changes of early renal function in patients with diabetic nephropathy with contrast-enhanced ultrasound and its clinical significance

GUO Xin-min 1,2, JIN Hong 2,PAN Li-wen 2,CHEN Hui 2,LIU Wei 2 ,QUAN Xian-yue1   

  1. 1.Department of Medical Imaging,Zhujiang Hospital,Southern Medical University,Guangzhou 510280,China;2.Department of Ultrasonic Diagnosis,Fourth Affiliated Hospital,Jinan University,Guangzhou 510220,China
  • Received:2012-09-03 Online:2013-01-28 Published:2013-01-30

摘要: 目的:通过超声造影(CEUS)定量分析糖尿病肾病(DN)患者肾血流灌注参数改变,探讨该技术在诊断DN患者早期肾功能改变中的价值。方法:40例糖尿病患者根据Mogensen分期标准分为正常白蛋白尿组(Ⅰ组)及早期DN组(Ⅱ组),15例健康志愿者为对照组(N组)。所有检查者均行肾CEUS灌注成像,并用QontraXt图像分析软件在肾皮质选取感兴趣区域(ROI),生成时间-强度曲线(TIC),获得肾血流灌注参数。结果:CEUS能清晰显示造
影剂在肾脏的灌注过程,与N组比较,Ⅰ组患者肾脏局部血容量(RBV)增多、达峰时间(TTP)和平均渡越时间(MTT)延长,差异有统计学意义( P<0.05 ),而达峰强度(DPI)及局部血流量(RBF)组间比较差异无统计学意义(P>0.05 );与N组及Ⅰ组比较,Ⅱ组患者RBV、TTP和MTT 明显增高,DPI、RBF明显降低,差异均有统计学意义( P< 0.05 )。结论:CEUS技术分析早期DN患者血流灌注参数的改变,可以评估DN患者早期肾功能异常。

关键词: 超声检查, 造影剂, 糖尿病肾病, 肾功能

Abstract: Objective  To quantitively assess the parameter alteration of renal blood flow in patients with diabetic nephropathy (DN)  with the contrast-enhanced ultrasound (CEUS),and to  evaluate the value of the technique  in diagnosis of early renal function changes of DN patients.Methods
 40 diabetic patients were equally divided into two groups according to Mogensen’[KG-*3]s staging criteria: normal albuminuria group(group Ⅰ) and
early DN group(group Ⅱ);and 15 cases of healthy volunteers were used as control group (N group)(n=15).All subjects were performed renal CEUS perfusion imaging,and QontraXt image analysis software was applied to select the region of interest (ROI) in the renal cortex.Then the time intensity curve (TIC) and kidney blood perfusion parameters were collected.Results  The renal blood perfusion was clearly shown in real time CEUS;compared with N group,the time to peak (TTP),regional blood volume (RBV),and mean transit time (MTT) of the patients in group Ⅰ were increased,there were significant differences (P<0.05);but there were no significant differences of derived peak intensity (DPI ) and regional blood flow (RBF ) between two groups (P> 0.05).Compared with group Ⅰ and N group,the RBV,TTP and MTT of the patients were increased,the DPI and RBF were reduced in group Ⅱ,there were significant differences 0.05).Conclusion The CEUS technical analysis can be used in evaluating renal abnormality of the DN patients in early period by showing the changes of renal perfusion parameters.

Key words: ultrasound examination, contrast agents, diabetic nephropathy, renal function

中图分类号: 

  • R587.1